We've diagnosed every failure a residential cooling system can develop. These are the issues our clients call us about most often.
A unit that will not start at all usually has a failed capacitor, a burned contactor, or a tripped safety switch caused by the compressor drawing excess current. Each of these has a distinct electrical signature that shows up during a proper diagnostic check. We test the full electrical circuit before recommending a repair so the right component gets replaced.
A system that runs continuously without reaching the set temperature is almost always working against low refrigerant charge, a fouled coil, or a failing capacitor reducing compressor output. The longer this runs uncorrected, the more strain it places on the compressor. We measure pressure, check amperage, and inspect the coil to identify the specific cause before any repair work begins.
A slow refrigerant leak causes the system to gradually lose cooling capacity, often over weeks or months before the homeowner notices. Topping up the charge without repairing the leak only delays the problem returning. We locate the leak source, complete the repair, and recharge the system to the manufacturer's specified pressure before testing the result.
Grinding, rattling, or squealing from the condenser unit usually points to a worn fan motor bearing, a loose fan blade, or debris caught in the housing. A grinding compressor is a more serious sign that internal wear has progressed significantly. We inspect the outdoor unit thoroughly and explain what is causing the noise and what the repair involves before proceeding.
Repeated breaker trips are a sign the compressor or a motor is drawing more current than the circuit is designed to handle. A weak capacitor, a dirty coil making the compressor overwork, or failing motor windings are the most common reasons. Continuing to reset the breaker without a diagnosis risks a full compressor burnout, which is significantly more expensive to repair or replace.
A frozen evaporator coil that has thawed or a blocked condensate drain line is responsible for the majority of water damage calls related to air conditioning. A frozen coil usually means restricted airflow or low refrigerant, not just a blocked drain. We check both the coil condition and the drain system to understand the root cause rather than just clearing the blockage.
An air conditioner that turns on and off every few minutes is short cycling, which puts heavy stress on the compressor and dramatically shortens the system's life. The most common causes are a thermostat issue, a tripping safety switch, an overcharged refrigerant circuit, or a compressor that is losing efficiency. We diagnose the control sequence and system pressures to identify what is triggering the short cycle.
Ice on the evaporator coil or refrigerant lines indicates that the coil is running colder than the airflow can keep it from freezing. This is caused by low refrigerant charge, a blocked air filter, or a failing blower motor reducing airflow significantly. Running a frozen system risks compressor damage as liquid refrigerant backs up into the compressor instead of returning as vapor.
When the system runs normally but one or more rooms stay warm, the issue is usually airflow-related: blocked or undersized ducts, a dirty filter restricting supply air, or a damper stuck in the closed position. In some cases the evaporator coil is partially restricted, reducing the volume of conditioned air reaching the space. We test airflow at the registers and trace the restriction back to its source.
Our AC stopped cooling two days before a major heat warning and Gas Services Edmonton got someone out the same afternoon. Turned out to be a failing capacitor and it was replaced in under an hour. Huge relief for our family.
I called expecting them to just add refrigerant but the technician explained why that wouldn't fix anything long term. He found a small leak in the line set, sealed it, and recharged the system properly. Running perfectly since.
Our compressor issue needed a part that wasn't on the truck so we waited two extra days for it to arrive. The communication throughout was good and the actual repair was done quickly once the part showed up.
I expected to be told I needed a whole new system but the technician from Gas Services Edmonton explained our unit was still a good repair candidate at 7 years old. Saved us thousands and the AC runs like new.
The technician walked me through what he was checking and why before touching anything, which I really appreciated. He found a stuck contactor that was making the unit run nonstop. Clear pricing and no surprises.
Called in the morning about warm air coming from the vents and had a technician at our door by early afternoon. Gas Services Edmonton diagnosed a frozen coil from a dirty filter and had us cooling again within the hour.
Contact Gas Services Edmonton today for expert HVAC repair, installation, and maintenance services in Edmonton area.
Call us directly or send a message using the form, whichever works best for you.
CALL US (587) 805-0530 EMAIL US Click to send a messageContact us! Our conversation stays private.