Get Your Quote for Furnace Not Turning On
Fill the form below to inquire about Gas Services Edmonton's Furnace Not Turning On in Edmonton.
Fill the form below to inquire about Gas Services Edmonton's Furnace Not Turning On in Edmonton.
A furnace that won't turn on can fail for a number of reasons, and the right repair depends on accurate diagnosis. These are the issues our technicians encounter most often.
When the furnace shows no response at all to a thermostat call, the problem is usually a power supply issue, a tripped breaker, or a blown fuse on the control board. Ignoring a completely unresponsive furnace in cold weather can leave the home without heat for hours or longer. We trace the power path from the panel to the control board and identify exactly where continuity is lost.
A furnace that attempts ignition but shuts off after a few seconds is almost always experiencing a flame sensor fault, a blocked flue, or a pressure switch failure. Each failed attempt cycles the system into a safety lockout that becomes harder to reset without addressing the root cause. We read the fault codes, inspect the ignition sequence, and repair the specific component breaking the start cycle.
When the hot surface igniter heats up but the burner fails to light, the gas valve is likely not opening, or gas pressure to the unit is insufficient. Continuing to force ignition attempts without a flame present can allow unburned gas to accumulate, which is a safety concern. We test the gas valve, verify supply pressure, and determine whether the valve requires repair or replacement.
When the thermostat is set above room temperature but the furnace does not respond, the issue can lie in the thermostat itself, low-voltage wiring between the thermostat and the board, or the control board's receiver circuit. A misdiagnosis here often leads to unnecessary thermostat replacements that do not fix the problem. We test the signal at both ends and trace any wiring faults before recommending a replacement.
Power surges and outages can trip internal safety switches or cause the control board to enter a fault-lockout state, leaving the furnace unresponsive even after power is restored. Resetting the furnace manually without checking for underlying voltage damage can cause the board to fail prematurely. We inspect the board, verify all safety switches have reset properly, and confirm stable operation before closing the call.
A furnace circulating air without producing heat typically indicates a failed ignition sequence, a closed gas valve, or a tripped high-limit switch caused by restricted airflow. Running the system continuously in this state wastes energy and delays proper diagnosis. We identify whether the issue is in the gas supply side, the ignition system, or an airflow restriction and complete the correct repair.
Modern furnace control boards flash LED error codes that indicate which part of the startup sequence failed, though reading and interpreting these codes correctly requires training and experience. Clearing a code without fixing the underlying fault will result in the same lockout occurring again within one or two heating cycles. We decode the fault, locate the failed component, and resolve the issue rather than simply clearing the error.
A detectable gas odour during a startup attempt can indicate a leaking gas valve, a cracked heat exchanger allowing combustion gases to enter the air stream, or a supply line issue upstream of the furnace. This condition requires immediate attention and the home should be vacated until a licensed gas technician has assessed the system. We carry all required safety equipment and perform a full combustion and leak check before restoring the system to service.
A pressure switch fault prevents the furnace from completing its startup sequence by stopping the gas valve from opening until the inducer motor confirms correct venting pressure. Common causes are a blocked condensate drain, a cracked inducer housing, or a failed pressure switch diaphragm. We check the entire venting and drainage path before testing the switch itself to avoid replacing a component that is not the root cause.
Woke up to a cold house and no idea what was wrong. Called Gas Services Edmonton and someone was here within a few hours. Turned out to be a failed ignitor, replaced on the spot, heat back on before dinner.
The technician knew almost immediately it was a dirty flame sensor based on how the furnace was clicking. Cleaned it, tested the system twice, and explained why it happens over time. Quick and reassuring.
Our control board needed replacing and it wasn't something on the truck, so we waited an extra day for the part to arrive. The technician from Gas Services Edmonton kept us updated the whole time and the furnace has run perfectly since.
Before booking a visit I called to ask what to check myself. The person on the phone walked me through the breaker and thermostat, which actually solved it. Saved me a service call and I really appreciated the honesty.
We noticed a faint gas smell and called right away. Gas Services Edmonton had someone out fast and confirmed it was a minor valve issue, not a major leak, but they treated it seriously the whole time. Felt genuinely cared for.
We had the same no-heat problem twice last winter with another company. This time the technician actually traced it to a venting issue causing the pressure switch to trip repeatedly and fixed the real cause. Hasn't happened since.
Contact Gas Services Edmonton today for expert HVAC repair, installation, and maintenance services in Edmonton area.
Call us directly or send a message using the form, whichever works best for you.
CALL US (587) 805-0530 EMAIL US Click to send a messageContact us! Our conversation stays private.